ALPHA BRIDGE LAYER 2 Switches (AS200/16/I2S)
Product Overview
The AS200/16/I2S is the highly reliable Layer 2+ managed industrial Ethernet switch with 16-port 10/100/1000-T RJ45 and 2-port 1G/2.5GBase-X SFP slots. It supports ERPS redundant network and the self-recovery mechanism is less than 20ms on full load which allows you to scheme a reliable Ethernet network by building a redundant ring topology as your back-up solution. It also supports IPv4/IPv6 static routing, DHCP server and robust Layer 2 management and secure function, which all making them ideal for large-scale industrial networks.
AS200/16/I2S is a high cost-effective easy-to-use device, which provides essential industrial Ethernet networking function, including wide range power input 12-58VDC, redundant power design with polarity reverse/over-voltage/over-current protection, robust IP40 fan-less housing with Din-rail installation, wide operation temperature from -40°C to 75°C as well as high-level EMI/EMC capability. It is the best choice for heavy industrial factory, transportation, oil & gas, chemical, IP Surveillance and processing automation area where environmental conditions are harsh and critical.
Product Features
- 16*10/100/1000Base-T RJ45, 2*1G/2.5GBase-X SFP
- Redundant power DC 12-58V input with polarity reverse/over-voltage/over-current protection
- Support one digital output for relay alarm (terminal block Pin 5/6)
- Layer 3 features: Support IPv4/IPv6 static routing, DHCP server
- Support Layer 2 management function: VLAN/VLAN Classification/QinQ/STP, RSTP, MSTP/Port Mirroring/DHCP/Multicast/ACL/IGMP/QoS/LLDP/802.1X/Dying Gasp/SFP DDM/IPV6 management/Web/ SNMP/Telnet/TFTP/Web upgrading
- Support G.8032 ERPS protocol, recovery time ≤20ms
- Support 6KV surge protection and ESD: Air-15kV, Contact-8kV Protection
- IP40 fan-less and Din-rail hardware design
- Operation temperature: -40℃ ~ +75℃
Product Specifications
| Model No. | AS200/16/I2S | |
| Interface | Fiber ports | Copper RJ45 ports |
| 2 | 16 | |
| Ethernet | 16*10/100/1000Base-T RJ45 2*1G/2.5GBase-X SFP | |
| Management port | 1*RJ45 Console port (115200,8,N,1) | |
| Alarm port | One digital output for relay alarm alarm relay current carry ability:1A@24VDC | |
| Standard | IEEE 802.3 10Base-T Ethernet IEEE 802.3u 100Base-TX Ethernet IEEE 802.3ab 1000Base-T Ethernet IEEE 802.3z 1000Base-X Ethernet IEEE802.3x Flow Control and Back Pressure IEEE 802.1D Spanning Tree Protocol IEEE 802.1w Rapid Spanning Tree Protocol IEEE 802.1Q VLAN ITU-T G.8032 ERPS IEEE 802.1X Port Authentication Network Control IEEE 802.1ab LLDP IEEE 802.3ad LACP | |
| LED Indicators | ||
| P (Power indicator) | Off: the device is power off or failed | |
| S (System status indicator) | Blinking: device initialization | |
| 1-16 (Copper ports indicators) Green | Off: ports link down | |
| On: ports link up | ||
| Blinking: data on TX/RX | ||
| 1-16 (Copper Speed indicators) Yellow | Off: port on 10/100M | |
| On: port on 1000M | ||
| 17-18 (Fiber ports indicators) Green | Off: ports link down | |
| On: ports link up | ||
| Blinking: data on TX/RX | ||
| Power parameter | ||
| Input voltage | 12-58V DC, redundant power input | |
| Input current | 1.3A Max | |
| Total power consumption | Full loading ≤15W | |
| Connector | Removable 6-pin terminal block, Pin 5-6 for relay alarm | |
| Reverse polarity protection | Support | |
| Over-voltage protection | Support | |
| Over-current protection | Support | |
| Layer 2 functions | ||
| Port aggregation | Support GE port aggregation Support 2.5GE aggregation Support static aggregation Support LACP dynamic aggregation Up to 64 aggregation groups and up to 8 ports per group | |
| Port features | Port mirroring (One-to-One, Many-to-One) Support loop detection (Port-based; VLAN-based) Support broadcast storm suppression (broadcast; unknown multicast; unknown unicast) | |
| Mac-address table management | Support static Mac-address management Support dynamic Mac-address Management Support filtering Mac-address Support MAC limit based on port and VLAN Support MAC flapping based on port and VLAN | |
| VLAN | Support access mode Support trunk mode Support hybrid mode | |
| VLAN classification | Mac Based VLAN IP Based VLAN Protocol Based VLAN | |
| GVRP | Normal mode Fixed mode Forbidden mode | |
| QinQ | Port-based QinQ VLAN-based QinQ (VLAN-stacking; VLAN-mapping) Flow-based QinQ | |
| LLDP | LLDP (Link Layer Discovery Protocol) | |
| Ring network protocol | Support IEEE802.1D-STP Support IEEE802.1W-RSTP Support IEEE802.1S-MSTP Support G.8032 ERPS protocol, single ring, sub-Ring and major ring Recovery time ≤20ms | |
| L2 Multicast | ||
| IGMP snooping | Support IGMP snooping | |
| Group address | Support group address | |
| Security functions | ||
| Connector | Removable 6-pin terminal block, Pin 5-6 for relay alarm | |
| Reverse polarity protection | Support | |
| Over-voltage protection | Support | |
| Over-current protection | Support | |
| Layer 2 functions | ||
| Port aggregation | Support GE port aggregation Support 2.5GE aggregation Support static aggregation Support LACP dynamic aggregation Up to 64 aggregation groups and up to 8 ports per group | |
| Port features | Port mirroring (One-to-One, Many-to-One) Support loop detection (Port-based; VLAN-based) Support broadcast storm suppression (broadcast; unknown multicast; unknown unicast) | |
| Mac-address table management | Support static Mac-address management Support dynamic Mac-address Management Support filtering Mac-address Support MAC limit based on port and VLAN Support MAC flapping based on port and VLAN | |
| VLAN | Support access mode Support trunk mode Support hybrid mode | |
| VLAN classification | Mac Based VLAN IP Based VLAN Protocol Based VLAN | |
| GVRP | Normal mode Fixed mode Forbidden mode | |
| QinQ | Port-based QinQ VLAN-based QinQ (VLAN-stacking; VLAN-mapping) Flow-based QinQ | |
| LLDP | LLDP (Link Layer Discovery Protocol) | |
| Ring network protocol | Support IEEE802.1D-STP Support IEEE802.1W-RSTP Support IEEE802.1S-MSTP Support G.8032 ERPS protocol, single ring, sub-Ring and major ring Recovery time ≤20ms | |
| L2 Multicast | ||
| IGMP snooping | Support IGMP snooping | |
| Group address | Support group address | |
| Security functions | ||
| Telnet server | Support telnet server | |
| Telnet client | Support telnet client | |
| SSH server | Support SSH server | |
| TACACS | Support TACACS (the terminal access controller accesses the control system) | |
| sflow | Support network traffic analysis | |
| TFTP | Support TFTP Client | |
| Layer 3 functions | ||
| ARP | ARP table aging | |
| DHCP server | ||
| IPv4 / IPv6 | static routing | |
| Switching features | ||
| Switching capacity | 42Gbps | |
| Packet forwarding rate | 62.5Mpps | |
| MAC address table | 16K | |
| VLAN | 4K | |
| Buffer | 12Mbit | |
| Forwarding delay | <5us | |
| Jumbo Frame | Support 10Kbytes | |
| MDX/MIDX | Support | |
| Watchdog | Support | |
| Mechanical structure | ||
| Case protection | IP40 | |
| Installation method | Din-rail | |
| Dimension(W*D*H)mm | 54*115*158mm | |
| Weight | 1.45 kg | |
| Operating environment | ||
| Operating temperature | -40℃~+75℃ | |
| Storage/transportation temperature | -40℃~+85℃ | |
| Relative humidity | Operation humidity: 10%-90%RH Storage humidity: 5%-95%RH | |
| Industrial Standard | ||
| EMS | Surge protection of power: IEC 61000-4-5 6KV/4KV(8/20us) Surge protection of Ethernet ports: IEC 61000-4-5 6KV/2KV(10/700us) RS: IEC 61000-4-3 80 MHz-1 GHz: 10 V/m EFT: IEC 61000-4-4 4K/2K CS: IEC 61000-4-6 10V ESD: IEC 61000-4-2 Contact: 8K; Air: 15K | |
| EMI | FCC Part 15B Class A | |
| Shock | IEC 60068-2-27 | |
| Free fall | IEC 60068-2-32 | |
| Vibration | IEC 60068-2-6 | |
| Certification | CCC/CE/UKCA/RoHS/REACH/FCC | |
| MTBF | >200,000 hours | |
Ordering Information
| Item | Description |
| AS200/16/I2S | 24-port Gigabit RJ45 + 4-port Gigabit SFP Lite-L3 Managed Industrial Switch; dual industrial-grade DC12~55V redundant power inputs; operating temperature: -40~75°C; lightning protection level of 6KV; IP40; DIN-rail installation. |