Alpha Bridge AQSFP28-100G-eLR4
This product is a 100Gb/s transceiver module designed for optical communication applications compliant to 100GBASE-LR of the IEEE 802.3ba standard. The module converts 4 input channels of 25Gb/s electrical data to 4 channels of LAN WDM optical signals and then multiplexes them into a single channel for 100Gb/s optical transmission. Reversely on the receiver side, the module DE multiplexes a 100 GB/s optical input into 4 channels of LAN WDM optical signals and then converts them to 4 output of electrical data. The central wavelengths of the 4 LAN WDM channels are 1295.56, 1300.05, 1304.58 and 1309.14nm as members of the LAN WDM wavelength grid defined in IEEE 802.3ba. The high-performance cooled LAN WDM DFB transmitters and high sensitivity PIN receivers provide superior performance for 100Gigabit Ethernet applications up to 20km links and compliant to optical interface with 100GBASE-LR4 requirements specified in IEEE 802.3ba Clause 88.
The Product is designed with form factor optical/electrical connection and digital diagnostic interface according to the QSFP+ Multi-Source Agreement (MSA). It has been designed to meet the harshest external operating conditions including temperature, humidity and EMI interference.
Features
- Hot pluggable QSFP28 MSA form factor
- Compliant to IEEE 3ba 100GBASE-LR4
- Digital diagnostic monitoring support
- Hot pluggable 38 pin electrical interface
- Transmitter cooled 4x25Gb/s LAN WDM DFB TOSA (1295.56, 05,1304.58, 1309.14nm)
- Receiver 4x25G PIN ROSA
- Maximum power consumption 4W
- LC duplex connector
- Supports 1Gb/s bit rate
- Up to 20kmreach for 652 SMF
- Commercial case temperature range of 0°C to 70°C
- Single 3V power supply
- RoHS-6 compliant
Application
- 100GBASE-LR4 100G Ethernet Links
- Infiniband QDR and DDR interconnects
- Datacenter and Enterprise networking
Absolute Maximum Ratings AQSFP28-100G-eLR4
| Parameter | Symbol | Min. | Max. | Units | Note |
| Storage Temperature | Ts | -40 | 85 | °C | |
| Max Supply Voltage | Vcc | -0.5 | 3.6 | V | |
| Relative Humidity | RH | 0 | 85 | % | 1 |
| Damage Threshold, each Lane | THd | 5.5 | dBm | ||
| Operating Case Temperature | TOP | 0 | 70 | °C |
Recommended Operating Conditions AQSFP28-100G-eLR4
| Parameter | Symbol | Min. | Max. | Units | Typ. |
| Case operating Temperature | Top | 0 | 70 | °C | |
| Supply Voltage | Vcc | 3.135 | 3.465 | V | 3.3 |
| Link distance with G.652 | D | 0.002 | 20 | KM | |
| Data Rate, each lane | Gb/s | 25.78125 | |||
| Data Rate Accuracy | -100 | 100 | ppm | ||
| Control Input Voltage-High | 2 | Vcc | V | ||
| Control Input Voltage-Low | 0 | 0.8 | V |
Transmitter Electro-optical Characteristics AQSFP28-100G-eLR4
| Parameter | Symbol | Min. | Typ. | Max. | Units | Note |
| Transmit wave lengths | L0 | 1294.53 | 1295.56 | 1296.59 | nm | |
| L1 | 1299.02 | 1300.05 | 1301.09 | nm | ||
| L2 | 1303.54 | 1304.58 | 1305.63 | nm | ||
| L3 | 1308.09 | 1309.14 | 1310.19 | nm | ||
| Signaling Speed per Lane | 25.78125± 100 ppm | Gb/s | ||||
| Side-mode Suppression Ratio | SMSR | 30 | dB | |||
| Total Average Launch Power | PT | 10.5 | dBm | |||
| Average launch power, each Lane | PAVG | 0 | 4.5 | dBm | ||
| Optical Modulation Amplitude (OMA), each lane | POMA | 0.5 | 4.5 | dBm | ||
| Launch Power in OMA minus Transmitter and dispersion penalty (TDP), each lane | -2.3 | 3.6 | dBm | |||
| Transmitter and Dispersion Penalty (TDP), each lane | TDP | 2.2 | dB | |||
| Extinction Ratio | ER | 4 | dB | |||
| Difference in Launch Power between any Two Lances (OMA) | Ptx,diff | 5 | dB | |||
| RIN20OMA | RIN | -130 | dB/Hz | |||
| Optical Return Loss Tolerance | TOL | 20 | dB | |||
| Transmitter Reflectance | RT | -12 | dB | |||
| Average Launch Power OFF Transmitter, each lane | Poff | -30 | dBm | |||
| Mask margin | 5 | % | ||||
| Transmitter eye mask definition {X1, X2,X3, Y1, Y2, Y3} | {0.25, 0.4, 0.45, 0.25, 0.28, 0.4} | 2 | ||||
Receiver Electro-optical Characteristics AQSFP28-100G-eLR4
| Parameter | Symbol | Min. | Typ. | Max. | Units | Note |
| Average Receiver Power, each Lane | -12.6 | 4.5 | dBm | |||
| Receiver power, each lane (OMA) | -3.5 | dBm | ||||
| Receiver reflectance | RR | -26 | dB | |||
| Difference in receive power between any two lanes (Average and OMA) | 5.5 | dB | ||||
| Receiver sensitivity (AOP), each lane | SEN | -8.6 | dBm | 2 | ||
| Stressed Receiver Sensitivity (OMA), each lane | -6.8 | dBm | 4 | |||
| Receiver 3 dB electrical upper cutoff frequency, each lane | Fc | 31 | GHz | |||
| Damage Threshold, each Lane | THd | 5.5 | dBm | 3 | ||
| LOS Assert | LOSA | -30 | dBm | |||
| LOS Deassert | LOSD | -13 | dBm | |||
| LOS Hysteresis | LOSH | 0.5 | dB | |||
| Conditions of Stress Receiver Sensitivity Test (Note 5) | ||||||
| Vertical Eye Closure Penalty, each lane | 1.8 | dB | ||||
| Stressed Eye J2 Jitter, each lane | 0.3 | UI | ||||
| Stressed Eye J9 Jitter, each lane | 0.47 | UI | ||||
Pin Descriptions AQSFP28-100G-eLR4
| Pin | Symbol | Description | Notes |
| 1 | GND | Ground | 1 |
| 2 | Tx2n | Transmitter Inverted Data Input | |
| 3 | Tx2p | Transmitter Non-Inverted Data Input | |
| 4 | GND | Ground | 1 |
| 5 | Tx4n | Transmitter Inverted Data Input | |
| 6 | Tx4p | Transmitter Non-Inverted Data Input | |
| 7 | GND | Ground | 1 |
| 8 | ModSelL | Module Select | |
| 9 | ResetL | Module Reset | |
| 10 | Vcc Rx | +3.3V Power Supply Receiver | 2 |
| 11 | SCL | 2-wire serial interface clock | |
| 12 | SDA | 2-wire serial interface data | |
| 13 | GND | Ground | 1 |
| 14 | Rx3p | Receiver Non-Inverted Data Output | |
| 15 | Rx3n | Receiver Inverted Data Output | |
| 16 | GND | Ground | 1 |
| 17 | Rx1p | Receiver Non-Inverted Data Output | |
| 18 | Rx1n | Receiver Inverted Data Output | |
| 19 | GND | Ground | 1 |
| 20 | GND | Ground | 1 |
| 21 | Rx2n | Receiver Inverted Data Output | |
| 22 | Rx2p | Receiver Non-Inverted Data Output | |
| 23 | GND | Ground | 1 |
| 24 | Rx4n | Receiver Non-Inverted Data Output | |
| 25 | Rx4p | Receiver Inverted Data Output | |
| 26 | GND | Ground | 1 |
| 27 | ModPrsL | Module Present | |
| 28 | IntL | Interrupt | |
| 29 | Vcc Tx | +3.3V Power supply transmitter | 2 |
| 30 | Vcc1 | +3.3V Power supply | 2 |
| 31 | LP Mode | Lower Power Mode | |
| 32 | GND | Ground | 1 |
| 33 | Tx3p | Transmitter Non-Inverted Data Input | |
| 34 | Tx3n | Transmitter Inverted Data Input | |
| 35 | GND | Ground | 1 |
| 36 | Tx1p | Transmitter Non-Inverted Data Input | |
| 37 | Tx1n | Transmitter Inverted Data Input | |
| 38 | GND | Ground | 1 |
Ordering information AQSFP28-100G-eLR4
| Model Number | Part Number | Voltage | Temperature |
| AQSFP28-100G-eLR4 | OPCW-S20 -13-CBD | 3.3V | 0°C to 70 °C |