Alpha Bridge AB-25G-40T Datasheet

Product Features

  • Up to 78Gbps Data Links
  • Up to 40km transmission on SMF
  • 1270nm/1310nm DFB Laser and APD receiver
  • Metal enclosure, for lower EMI
  • 2-wire interface with integrated Digital Diagnostic monitoring
  • Hot-pluggable SFP28 footprint
  • Compliant with SFP+ MSA and SFF-8472 with duplex LC receptacle
  • Single 3V power supply
  • Power dissipation < 5 W
  • Operating case temperature:0 to +70°C

Applications

  • 25GBASE-ER
  • eCPRI and CPRI

Standard

  • Compliant with SFF-8472 &8431
  • RoHS Compliant.

Absolute Maximum Ratings

Parameter Symbol Min Max Unit
Storage Temperature Ts -40 85 °C
Relative Humidity RH 5 95 %
Power Supply Voltage VCC -0.3 4 V
Signal Input Voltage VSI Vcc-0.3 Vcc+0.3 V
Rx Damage Threshold PRdmg -3   dBm

Recommended Operating Conditions

Parameter Symbol Min Typical Max Unit
Case Operating Temperature Tcase 0   70 °C
Power Supply Voltage VCC 3.14 3.3 3.47 V
Power Supply Current ICC     420 mA
Data Rate BR   25.78   Gbps
Transmission Distance TD     40 km
Coupled fiber Single mode fiber

Optical and Electrical Characteristics

Parameter Symbol Min Typical Max Unit Notes
Transmitter
Centre Wavelength λc 1260 1270 1280 nm  
Spectral Width(-20dB) Δλ     1 nm  
Average Output Power Pout 0   6 dBm  
Average Launched Power(Laser Off) Poff     -30 dBm  
Extinction Ratio ER 3.5     dB 1
Input differential impedance Rin   100   Ω 2
Single ended data input swing Vin,pp 180   700 mV  
TX Disable Disable 2   Vcc+0.3 V
Enable   0   0.8 V  
TX Fault Fault 2   Vcc+0.3 V
Normal   0   0.8 V  
Output Eye Mask {0.31,0.4,0.45,0.34,0.38,0.4}
Receiver
Centre Wavelength λc 1300 1310 1320 nm  
Receiver Sensitivity       -17.5 dBm 3
Input Saturation Power (Overload)   -6     dBm  
Los Of Signal Assert Pa -35     dBm  
Los Of Signal De-assert Pd     -19 dBm  
LOS -Hysteresis PHys 0.5 2 6 dB  
Differential data output swing Vout,pp 300   850 mV 4
LOS High 2   Vcc+0.3 V
Low       0.8 V  

Pin Descriptions

Pin Symbol Name/Description Notes
1 Veet Transmitter Ground (Common with Receiver Ground) 1
2 Tfault Transmitter Fault. 2
3 Tdis Transmitter Disable. Laser output disabled on high or open. 3
4 SDA 2-wire Serial Interface Data Line 4
5 SCL 2-wire Serial Interface Clock Line 4
6 MOD_ABS Module Absent. Grounded within the module 4
7 RS0 Rate Select 0, internal pull down 5
8 LOS Loss of Signal indication. Logic 0 indicates normal operation. 6
9 RS1 Rate Select 1, internal pull down 5
10 Veer Receiver Ground (Common with Transmitter Ground) 1
11 Veer Receiver Ground (Common with Transmitter Ground) 1
12 RD- Receiver Inverted DATA out.AC Coupled  
13 RD+ Receiver Non-inverted DATA out.AC Coupled  
14 Veer Receiver Ground (Common with Transmitter Ground) 1
15 Vccr Receiver Power Supply  
16 Vcct Transmitter Power Supply  
17 Veet Transmitter Ground (Common with Receiver Ground) 1
18 TD+ Transmitter Non-Inverted DATA in. AC Coupled.  
19 TD- Transmitter Inverted DATA in. AC Coupled.  
20 Veet Transmitter Ground (Common with Receiver Ground) 1

Ordering information

Part Number Description
AB-25G-40T 1270T/1310R,25.78Gbps, LC,40km,0°C~+70°C, with DDM
Scroll to Top