Alpha Bridge AQSFP28-100G-eLR4

This product is a 100Gb/s transceiver module designed for optical communication applications compliant to 100GBASE-LR of the IEEE 802.3ba standard. The module converts 4 input channels of 25Gb/s electrical data to 4 channels of LAN WDM optical signals and then multiplexes them into a single channel for 100Gb/s optical transmission. Reversely on the receiver side, the module DE multiplexes a 100 GB/s optical input into 4 channels of LAN WDM optical signals and then converts them to 4 output of electrical data. The central wavelengths of the 4 LAN WDM channels are 1295.56, 1300.05, 1304.58 and 1309.14nm as members of the LAN WDM wavelength grid defined in IEEE 802.3ba. The high-performance cooled LAN WDM DFB transmitters and high sensitivity PIN receivers provide superior performance for 100Gigabit Ethernet applications up to 20km links and compliant to optical interface with 100GBASE-LR4 requirements specified in IEEE 802.3ba Clause 88.

The Product is designed with form factor optical/electrical connection and digital diagnostic interface according to the QSFP+ Multi-Source Agreement (MSA). It has been designed to meet the harshest external operating conditions including temperature, humidity and EMI interference.

Features

  • Hot pluggable QSFP28 MSA form factor
  • Compliant to IEEE 3ba 100GBASE-LR4
  • Digital diagnostic monitoring support
  • Hot pluggable 38 pin electrical interface
  • Transmitter cooled 4x25Gb/s LAN WDM DFB TOSA (1295.56, 05,1304.58, 1309.14nm)
  • Receiver 4x25G PIN ROSA
  • Maximum power consumption 4W
  • LC duplex connector
  • Supports 1Gb/s bit rate
  • Up to 20kmreach for 652 SMF
  • Commercial case temperature range of 0°C to 70°C
  • Single 3V power supply
  • RoHS-6 compliant

Application

  • 100GBASE-LR4 100G Ethernet Links
  • Infiniband QDR and DDR interconnects
  • Datacenter and Enterprise networking

Absolute Maximum Ratings AQSFP28-100G-eLR4

Parameter Symbol Min. Max. Units Note
Storage Temperature Ts -40 85 °C  
Max Supply Voltage Vcc -0.5 3.6 V  
Relative Humidity RH 0 85 % 1
Damage Threshold, each Lane   THd 5.5     dBm  
Operating Case Temperature   TOP 0   70   °C  

Recommended Operating Conditions AQSFP28-100G-eLR4

Parameter Symbol Min. Max. Units Typ.
Case operating Temperature Top 0 70 °C  
Supply Voltage Vcc 3.135 3.465 V 3.3
Link distance with G.652 D 0.002 20 KM  
Data Rate, each lane       Gb/s 25.78125
Data Rate Accuracy   -100 100 ppm  
Control Input Voltage-High   2 Vcc V  
Control Input Voltage-Low   0 0.8 V  

Transmitter Electro-optical Characteristics AQSFP28-100G-eLR4

Parameter Symbol Min. Typ. Max. Units Note
Transmit wave lengths L0 1294.53 1295.56 1296.59 nm  
L1 1299.02 1300.05 1301.09 nm  
L2 1303.54 1304.58 1305.63 nm  
L3 1308.09 1309.14 1310.19 nm  
Signaling Speed per Lane 25.78125± 100 ppm Gb/s  
Side-mode Suppression Ratio SMSR 30     dB  
Total Average Launch Power PT     10.5 dBm  
Average launch power, each Lane PAVG 0   4.5 dBm  
Optical Modulation Amplitude (OMA), each lane POMA 0.5   4.5   dBm  
Launch Power in OMA minus Transmitter and dispersion penalty (TDP), each lane       -2.3       3.6     dBm  
Transmitter and Dispersion Penalty (TDP), each lane   TDP       2.2   dB  
Extinction Ratio ER 4     dB  
Difference in Launch Power between any Two Lances (OMA) Ptx,diff     5 dB  
RIN20OMA RIN     -130 dB/Hz  
Optical Return Loss Tolerance TOL     20 dB  
Transmitter Reflectance RT     -12 dB  
Average Launch Power OFF Transmitter, each lane Poff       -30   dBm  
Mask margin   5     %  
Transmitter eye mask definition {X1, X2,X3, Y1, Y2, Y3}   {0.25, 0.4, 0.45, 0.25, 0.28, 0.4}   2

Receiver Electro-optical Characteristics AQSFP28-100G-eLR4

Parameter Symbol Min. Typ. Max. Units Note
Average Receiver Power, each Lane   -12.6   4.5 dBm  
Receiver power, each lane (OMA)       -3.5 dBm  
Receiver reflectance RR     -26 dB  
Difference in receive power between any two lanes (Average and OMA)         5.5   dB  
Receiver sensitivity (AOP), each lane SEN     -8.6 dBm 2
Stressed Receiver Sensitivity (OMA), each lane         -6.8   dBm   4
Receiver 3 dB electrical upper cutoff frequency, each lane Fc       31   GHz  
Damage Threshold, each Lane THd 5.5     dBm 3
LOS Assert LOSA -30     dBm  
LOS Deassert LOSD     -13 dBm  
LOS Hysteresis LOSH 0.5     dB  
Conditions of Stress Receiver Sensitivity Test (Note 5)
Vertical Eye Closure Penalty, each lane       1.8 dB  
Stressed Eye J2 Jitter, each lane       0.3 UI  
Stressed Eye J9 Jitter, each lane       0.47 UI  

          Notes:

  1. Even if th TDP< 1 dB, the OMA min must exceed the minimum value specified
  2. Hit ratio 5×10-5
  3. The receiver shall be able to tolerate, without damage, continuous exposure to a modulated optical input signal having this power level on one The receiver does not have to operate correctly at this input power.
  4. Measured with conformance test signal at receiver input for BER=1×10-12
  5. Vertical eye closure penalty, stressed eye J2 jitter, and stressed eye J9 jitter are test conditions for measwing stressed receiver They are not characteristics of the receiver.

Pin Descriptions AQSFP28-100G-eLR4

Pin Symbol Description Notes
1 GND Ground 1
2 Tx2n Transmitter Inverted Data Input  
3 Tx2p Transmitter Non-Inverted Data Input  
4 GND Ground 1
5 Tx4n Transmitter Inverted Data Input  
6 Tx4p Transmitter Non-Inverted Data Input  
7 GND Ground 1
8 ModSelL Module Select  
9 ResetL Module Reset  
10 Vcc Rx +3.3V Power Supply Receiver 2
11 SCL 2-wire serial interface clock  
12 SDA 2-wire serial interface data  
13 GND Ground 1
14 Rx3p Receiver Non-Inverted Data Output  
15 Rx3n Receiver Inverted Data Output  
16 GND Ground 1
17 Rx1p Receiver Non-Inverted Data Output  
18 Rx1n Receiver Inverted Data Output  
19 GND Ground 1
20 GND Ground 1
21 Rx2n Receiver Inverted Data Output  
22 Rx2p Receiver Non-Inverted Data Output  
23 GND Ground 1
24 Rx4n Receiver Non-Inverted Data Output  
25 Rx4p Receiver Inverted Data Output  
26 GND Ground 1
27 ModPrsL Module Present  
28 IntL Interrupt  
29 Vcc Tx +3.3V Power supply transmitter 2
30 Vcc1 +3.3V Power supply 2
31 LP Mode Lower Power Mode  
32 GND Ground 1
33 Tx3p Transmitter Non-Inverted Data Input  
34 Tx3n Transmitter Inverted Data Input  
35 GND Ground 1
36 Tx1p Transmitter Non-Inverted Data Input  
37 Tx1n Transmitter Inverted Data Input  
38 GND Ground 1

Ordering information AQSFP28-100G-eLR4

  Model Number   Part Number   Voltage   Temperature
AQSFP28-100G-eLR4 OPCW-S20 -13-CBD 3.3V 0°C to 70 °C